Specifications
Weight: 1 Kg. (2.2 lbs)
Size: 180 x 110 x 165 mm (7" x 4.5" x 6.5")
Batteries: 6 type AA cells, alkaline (IEC LR6) or rechargeable (IEC KR 15/51)
Battery life: Approximately 300 hours at 4 hours/day.
Paralysis time: Scale corrected to give true reading.
Meter integration time: 1 to 4 seconds set to match counting rate.
Radiation detector: Halogen quenched G-M tube.
Radiation detected: Gamma and X-rays only.
G-M tube supply: 300-700 Volts preset for tube type.
Overload protection: No meter 'fallback' with intensities at least 100 times full scale reading.
Main power: 12-18 V dc from mains unit.

Available Configurations
Type R: Monitoring High Level Dose Rates A monitor scaled over the range 0.5 to 5000 μSv h-1 (0.05 to 500 mR/h). The G-M tube is compensated to give a useful response from 45 keV to
1.5 MeV and above. It is not recommended for monitoring X-radiation from apparatus operating below 75 kVp.

Type G: Monitoring for Low Environmental Dose Rates Highly sensitive performance. The monitor is scaled over the range 0.05 to 75 μSv h-1 (0.005 to 7.5 mR/h). The useful energy range is 55 keVto 1.5 MeV and above. This instrument is not suitable for monitoring X-radiation.

Type D: A monitor using a partially compensated G-M tube to obtain an extended low energy response.
The instruments is scaled over the range of 0.5 to 1000 μSvh-1 (0.05 to 100 mR/h). The useful energy range is from 30 keV to 1.5 MeV but response is maintained down to at least 17 keV. It is suitable for measuring radiation from X-ray apparatus operating at or above 45 kVp.

Type X: This instrument is scaled 0.5 to 2000 counts per second and uses an end window G-M tube without energy compensation. It is sensitive to radiation down to 10keV and is therefore useful for locating X-ray leakage from a variety of systems including high voltage equipment where X-rays are generated adventitiously. It is not intended for measurement but as a relative check device.

Re-Calibration service is available for these products

Additional Information

Additional Accessories N/A
Product Code F00.1207

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  • Rohmann
  • Fujifilm
  • Johnson Allen
  • Chemetall
  • Magnaflux
  • Colenta
  • Tracerco
  • Gal Gage Co.
  • Tetenal
  • Radiographic Accessories Limited
  • Vertec
  • High Technology Sources Limited
  • Phoenix Inspection Systems Limited
  • AGFA
  • Wolf Safety Lamp Company
  • X-Rite
  • Balteua NDT
  • Karl Deutsch
This site uses cookies. By continuing to browse this site you are agreeing to our use of cookies. Find out more here.
x