Tel No: +44 (0) 1429 836655

sales@fidgeon.co.uk

Family business suppling the Non-Destructive Testing Industry since 1975

Dose Rae 2 Personal Radiation Dosimeter

£1.00
Product Code: F00.1188

Be the first to review this product

Availability: In stock

£1.00
OR

Quick Overview

DoseRAE 2 is a compact, direct-reading and alarming electronic personal radiation detector. It uses a diode and a scintillation crystal to detect X- and gamma radiation, and provides real-time monitoring of personal dose and dose rate. The real-time radiation dose rate monitoring allows immediate reaction in case of radiation occurrences and thus reduces the radiation exposure. By measuring dose equivalent and dose equivalent rate, this detector provides the functions of a dosimeter too. It also measures radiation exposure and exposure rate, which is appropriate for controlling the exposure of emergency responders to photon radiation.


Key Features

Stand-alone electronic dosimeter with LCD display Multiple units with reader and software can be used as a dosimetry system

Continuous digital dose rate readout in rem/h, Sv/h and R/h

Continuously accumulated total dose readout in rem, Sv and R

Prominent visible, audible, and vibration alarms

Long calibration life

Two operation keys, simple intuitive programming


Applications

Nuclear power plants

Environmental survey

Fire Departments

Hazardous Material Response Teams

Police

EMS

Military

Hospitals

Non Destructive Testing


Dosimeter Meets Detector :

Contains two separate sensors, CsI/photodiode and PIN diode.

The energy-compensated PIN diode provides high-dose-rate range coverage and accurate dose measurements, while the CsI (Cesium Iodide) scintillator provides fast response to low-level radiation.


Datalogging and Analysis:

DoseRAE 2 offers continuous datalogging with a large, 3,000-point datalog capacity. With associated software, the datalog can be downloaded via USB to a computer. This software is used for data display,analysis and record management.


Alarm Types:

Integrated loud audible, bright LEDs, and vibration alarms.


Total Dose Data:

Accurately accumulates real-time dose data.


National Standard Compliance:

DoseRAE 2 was designed in compliance with IEEE ANSI N42.20 standard, and the performance was tested at Oak Ridge National Laboratory, Tennessee, U.S.A.



Specifications


















































































Gamma Sensors CsI (TI) + photodiode (low environment radiation)

Energy-compensated PIN diode (level of radiation protection)
Dose Rate Range 0.01 μSv/h to 10 Sv/h (1 μR/h to 1140 R/h)
Accuracy of Dose Rate +/-20% (from 10 μSv/h to 10 Sv/h or from 1.14 mR/h to 1140 R/h )

+/-30% (from 0.01 μSv/h to 10 μSv/h or 1 μR/h to 1.14 mR/h)
Dose Range  0 μSv to 10 Sv (0 μR to 1140 R)
Dose Accuracy +/-15%
Energy Range 20 keV to 6 MeV for X- and gamma radiations
Size 3.3" x 2.2" x 0.4" (85 x 55 x 9.6 mm) without clip
Weight 1.8 oz. (50g) with battery and clip
Battery LIR2450 Rechargeable batteries
Operating Hours Up to 200 hours after each charge (one week continuous use)
Datalog Size More than 3000 data points
Datalog Interval User programmable, from 30 to 3,600 seconds
Communication USB interfaces with computer for datalog download
Alarms

Loud audible buzzer (85+dB @ 30 cm/12")

Highly visible LED lights

Built-in vibration alarm


Alarm Settings Dose alarm (adjustable from 1.0 μSv to 10 Sv or 114μR to 1140 R)

Dose rate alarm (adjustable from 1.0 μSv/h to 10 Sv/h or 114 μR/h to 1140 R/h)
Temperature -20 deg C to 50 deg C (-4 deg F to 122 deg F)
Humidity 0% to 95% (non-condensing)
IP Rating IP-54
Shock Resistance Passes drop test from 1.5 m (59")


DoseRAE 2 Supplied With:

DoseRAE 2 Electronic Personal Dosimeter with clip

Charging and PC communication cradle

USB communication cable

Protective silicone boot

CD with (1) ProRAE Dosimeter instrument configuration and data management software and (2) Users Guide

Protective pouch with alligator clip

Calibration and test certificate

Warranty/registration card


More Views

Details

DoseRAE 2 is a compact, direct-reading and alarming electronic personal radiation detector. It uses a diode and a scintillation crystal to detect X- and gamma radiation, and provides real-time monitoring of personal dose and dose rate. The real-time radiation dose rate monitoring allows immediate reaction in case of radiation occurrences and thus reduces the radiation exposure. By measuring dose equivalent and dose equivalent rate, this detector provides the functions of a dosimeter too. It also measures radiation exposure and exposure rate, which is appropriate for controlling the exposure of emergency responders to photon radiation.

Key Features
Stand-alone electronic dosimeter with LCD display Multiple units with reader and software can be used as a dosimetry system
Continuous digital dose rate readout in rem/h, Sv/h and R/h
Continuously accumulated total dose readout in rem, Sv and R
Prominent visible, audible, and vibration alarms
Long calibration life
Two operation keys, simple intuitive programming

Applications
Nuclear power plants
Environmental survey
Fire Departments
Hazardous Material Response Teams
Police
EMS
Military
Hospitals
Non Destructive Testing

Dosimeter Meets Detector :
Contains two separate sensors, CsI/photodiode and PIN diode.
The energy-compensated PIN diode provides high-dose-rate range coverage and accurate dose measurements, while the CsI (Cesium Iodide) scintillator provides fast response to low-level radiation.

Datalogging and Analysis:
DoseRAE 2 offers continuous datalogging with a large, 3,000-point datalog capacity. With associated software, the datalog can be downloaded via USB to a computer. This software is used for data display,analysis and record management.

Alarm Types:
Integrated loud audible, bright LEDs, and vibration alarms.

Total Dose Data:
Accurately accumulates real-time dose data.

National Standard Compliance:
DoseRAE 2 was designed in compliance with IEEE ANSI N42.20 standard, and the performance was tested at Oak Ridge National Laboratory, Tennessee, U.S.A.

Specifications

Gamma Sensors CsI (TI) + photodiode (low environment radiation)
Energy-compensated PIN diode (level of radiation protection)
Dose Rate Range 0.01 μSv/h to 10 Sv/h (1 μR/h to 1140 R/h)
Accuracy of Dose Rate +/-20% (from 10 μSv/h to 10 Sv/h or from 1.14 mR/h to 1140 R/h )
+/-30% (from 0.01 μSv/h to 10 μSv/h or 1 μR/h to 1.14 mR/h)
Dose Range  0 μSv to 10 Sv (0 μR to 1140 R)
Dose Accuracy +/-15%
Energy Range 20 keV to 6 MeV for X- and gamma radiations
Size 3.3" x 2.2" x 0.4" (85 x 55 x 9.6 mm) without clip
Weight 1.8 oz. (50g) with battery and clip
Battery LIR2450 Rechargeable batteries
Operating Hours Up to 200 hours after each charge (one week continuous use)
Datalog Size More than 3000 data points
Datalog Interval User programmable, from 30 to 3,600 seconds
Communication USB interfaces with computer for datalog download
Alarms

Loud audible buzzer (85+dB @ 30 cm/12")
Highly visible LED lights
Built-in vibration alarm

Alarm Settings Dose alarm (adjustable from 1.0 μSv to 10 Sv or 114μR to 1140 R)
Dose rate alarm (adjustable from 1.0 μSv/h to 10 Sv/h or 114 μR/h to 1140 R/h)
Temperature -20 deg C to 50 deg C (-4 deg F to 122 deg F)
Humidity 0% to 95% (non-condensing)
IP Rating IP-54
Shock Resistance Passes drop test from 1.5 m (59")

DoseRAE 2 Supplied With:
DoseRAE 2 Electronic Personal Dosimeter with clip
Charging and PC communication cradle
USB communication cable
Protective silicone boot
CD with (1) ProRAE Dosimeter instrument configuration and data management software and (2) Users Guide
Protective pouch with alligator clip
Calibration and test certificate
Warranty/registration card

Additional Information

Additional Accessories N/A
Product Code F00.1188

Details

DoseRAE 2 is a compact, direct-reading and alarming electronic personal radiation detector. It uses a diode and a scintillation crystal to detect X- and gamma radiation, and provides real-time monitoring of personal dose and dose rate. The real-time radiation dose rate monitoring allows immediate reaction in case of radiation occurrences and thus reduces the radiation exposure. By measuring dose equivalent and dose equivalent rate, this detector provides the functions of a dosimeter too. It also measures radiation exposure and exposure rate, which is appropriate for controlling the exposure of emergency responders to photon radiation.

Key Features
Stand-alone electronic dosimeter with LCD display Multiple units with reader and software can be used as a dosimetry system
Continuous digital dose rate readout in rem/h, Sv/h and R/h
Continuously accumulated total dose readout in rem, Sv and R
Prominent visible, audible, and vibration alarms
Long calibration life
Two operation keys, simple intuitive programming

Applications
Nuclear power plants
Environmental survey
Fire Departments
Hazardous Material Response Teams
Police
EMS
Military
Hospitals
Non Destructive Testing

Dosimeter Meets Detector :
Contains two separate sensors, CsI/photodiode and PIN diode.
The energy-compensated PIN diode provides high-dose-rate range coverage and accurate dose measurements, while the CsI (Cesium Iodide) scintillator provides fast response to low-level radiation.

Datalogging and Analysis:
DoseRAE 2 offers continuous datalogging with a large, 3,000-point datalog capacity. With associated software, the datalog can be downloaded via USB to a computer. This software is used for data display,analysis and record management.

Alarm Types:
Integrated loud audible, bright LEDs, and vibration alarms.

Total Dose Data:
Accurately accumulates real-time dose data.

National Standard Compliance:
DoseRAE 2 was designed in compliance with IEEE ANSI N42.20 standard, and the performance was tested at Oak Ridge National Laboratory, Tennessee, U.S.A.

Specifications

Gamma Sensors CsI (TI) + photodiode (low environment radiation)
Energy-compensated PIN diode (level of radiation protection)
Dose Rate Range 0.01 μSv/h to 10 Sv/h (1 μR/h to 1140 R/h)
Accuracy of Dose Rate +/-20% (from 10 μSv/h to 10 Sv/h or from 1.14 mR/h to 1140 R/h )
+/-30% (from 0.01 μSv/h to 10 μSv/h or 1 μR/h to 1.14 mR/h)
Dose Range  0 μSv to 10 Sv (0 μR to 1140 R)
Dose Accuracy +/-15%
Energy Range 20 keV to 6 MeV for X- and gamma radiations
Size 3.3" x 2.2" x 0.4" (85 x 55 x 9.6 mm) without clip
Weight 1.8 oz. (50g) with battery and clip
Battery LIR2450 Rechargeable batteries
Operating Hours Up to 200 hours after each charge (one week continuous use)
Datalog Size More than 3000 data points
Datalog Interval User programmable, from 30 to 3,600 seconds
Communication USB interfaces with computer for datalog download
Alarms

Loud audible buzzer (85+dB @ 30 cm/12")
Highly visible LED lights
Built-in vibration alarm

Alarm Settings Dose alarm (adjustable from 1.0 μSv to 10 Sv or 114μR to 1140 R)
Dose rate alarm (adjustable from 1.0 μSv/h to 10 Sv/h or 114 μR/h to 1140 R/h)
Temperature -20 deg C to 50 deg C (-4 deg F to 122 deg F)
Humidity 0% to 95% (non-condensing)
IP Rating IP-54
Shock Resistance Passes drop test from 1.5 m (59")

DoseRAE 2 Supplied With:
DoseRAE 2 Electronic Personal Dosimeter with clip
Charging and PC communication cradle
USB communication cable
Protective silicone boot
CD with (1) ProRAE Dosimeter instrument configuration and data management software and (2) Users Guide
Protective pouch with alligator clip
Calibration and test certificate
Warranty/registration card

Additional Information

Additional Accessories N/A
Product Code F00.1188

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  • Rohmann
  • Fujifilm
  • Johnson Allen
  • Chemetall
  • Magnaflux
  • Colenta
  • Tracerco
  • Gal Gage Co.
  • Tetenal
  • Radiographic Accessories Limited
  • Vertec
  • High Technology Sources Limited
  • Phoenix Inspection Systems Limited
  • AGFA
  • Wolf Safety Lamp Company
  • X-Rite
  • Balteua NDT
  • Karl Deutsch
This site uses cookies. By continuing to browse this site you are agreeing to our use of cookies. Find out more here.
x