Simple Operation

All versions of the DM5E have the same user-friendly operator keypad interface. This has a central Mode key, a calibration/on/off key, two function arrow keys to activate and set functional control and four arrow keys for adjusting parameter values and for navigating through the intuitive single level menu.
The keypad allows access to all calibration, set-up and measurement display modes of the instrument. With the DL version, a file display mode allows users to create and store thickness reading s in files. All calibration is menu-driven and the operator is guided through every step. There is a built-in calibration reminder, which can be set to remind the user to calibrate after a specified number of  measurements or after a given time period.
 

High Performance Probes

A new set of ultrasonic probes has been developed for the DM5E family to provide the instruments with optimized performance, even at very high temperatures.
The DA5xx series includes a 5 MHz standard probe for general purpose applications, a 2MHz version, for high penetration as well as a 7.5MHz fingertip probe to be used for "thin" materials. A newly developed 5MHz high temperature probe offers an operating range from -10 deg C up to +204 deg C (continuously).
 

Measurement Through Coating

Both the DM5E and the DM5E DL offer Dual Multi Measurement.
Virtually all components and structures subjected to thickness measurement will have some kind of protective coating. Such coatings, including paint, contribute significant error to thickness measurements of underlying metal walls when using conventional methods. In addition, the removal of coatings, and their subsequent reapplication, involves considerable cost and time. With the field proven Dual Multi feature there is no need to remove any protective coating.
It is only necessary to select Dual Multi mode, place the probe in position and take the measurement.

Flexible Data Processing

The DM5E DL has a built-in datalogger, with a capacity to store up a massive 50,000 reading in grid and linear files. This makes the measurement data available for further processing.
Using our UltraMATE software. Measurement data files can be transferred from the instrument to a PC., where they can be analyzed and stored.
Additionally the data files can directly be exported to MS Excel by means of a macro – in this case no additional and specific software will be needed.

Measurement Displays

All versions of the DM5E offer a range of measurement displays. These include:

Normal where the thickness value appears as large digits in the centre of the display

Mini Scan This is a minimum thickness scan and allows the user to run the probe over the wall surface. After the evaluation period, the minimum material thickness measured is displayed.

Maxi Scan. This is a maximum thickness scan and is exactly the same as a Mini Scan apart from the fact that the maximum thickness measured is displayed.

DIFF/RR%. This scan compares the measured thickness with a user-specified nominal thickness. The dimensional difference between the two values is displayed,as is the percentage difference.

B-Scan This displays a graphic representation of a B-scan showing minimum thickness values.

The graph is derived by measuring and recording at 1 point per second.
 

Measurement Reliability

Although thickness measurements are considered as a simple inspection task studies have shown that there is a risk for wrong thickness measurements.
Due to the complexity of certain thickness gages wrong instrument settings could result in faulty results.

With the new DM5E we offer the field approved, simple intuitive CL5 user interface and in addition to that the password protected Advanced Configuration Menuallows you to lock important settings and functions.

This means: no more faulty reading as a result of wrong calibration,or unintended changes to the instrument configuration.
 

Upgradeability

Fast, reliable measurement and reporting is in demand, enabling you to act fast on corrosion issues to ensure uptime and long life of your equipment and operations. Especially in the current economic conditions, investments have to be evaluated very carefully - the DM5E series offers flexible solutions, that are easily upgradeable to the changing situations and the related functionality needed.

Buy the instrument configuration needed today with the built-in ability to add additional features to the instrument when needed without having to send it back to us.

In case inspection needs are changing the DM5E series can be upgraded in the field by adding e.g. Dual Multi or datalogger functionality.

This unit is only available to end users within the EU and not for resale outside of the EU


 

Additional Information

Additional Accessories N/A
Product Code F25.0119

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  • Rohmann
  • Fujifilm
  • Johnson Allen
  • Chemetall
  • Magnaflux
  • Colenta
  • Tracerco
  • Gal Gage Co.
  • Tetenal
  • Radiographic Accessories Limited
  • Vertec
  • High Technology Sources Limited
  • Phoenix Inspection Systems Limited
  • AGFA
  • Wolf Safety Lamp Company
  • X-Rite
  • Balteua NDT
  • Karl Deutsch
This site uses cookies. By continuing to browse this site you are agreeing to our use of cookies. Find out more here.
x