+44 (0) 1429 836655 [email protected]

Ferrite Meter MF300Fm+ • Fidgeon

Products > >

Request Account

Ferrite Meter MF300Fm+

Clear
SKU: N/A Categories: ,

Description

MF300Fm+ Product Information

Measurement of Ferrite Number and Ferrite Percentage in stainless steel.

Industrial processing and chemical plants work at high temperatures and pressures, often with aggressive media; stainless steel is often the material of choice for these applications.  If the ferrite content of the steel steel is too low, then welding of stainless material may crack at elevated temperature or with high stress or vibration.  If the ferrite content is too high, the weld may be weaker and corrode.

To address the need to measure the amount of ferrite in a sample the Welding Research Council introduced the Ferrite Number (FN) as standardised value which related to the ferrite content of an equivalently magnetic weld metal.  The volume percentage of ferrite can be estimated at 70% of the FN but the relationship depends upon the type and origin of the stainless steel used and the measurement technique. The MF300Fm+ uses a transfer curve to convert measured FN to F%.

The Diverse Ferrite meter MF300Fm+ measures the Ferrite number (FN) of austenitic and duplex stainless steel weld material. It has a probe that is sensitive to ferrite content in a 80mm² area to a depth of approximately 1mm. Alternatively there is a small area probe with a sensitive area of 24mm² (4mm×6mm)

The instrument is calibrated using the secondary world standards validated by National Institute of Standards and Technology (NIST) in the USA. All 16 standards are used in the calibration giving an instrument with a measurement range from 0 to 115FN. Transfer standards are supplied with the instrument allowing performance to be verified at any time.

There are 5 MF300Fm+ probe options: P10, P10AC, P46, P10-2, P46-2 (second probe options)

Features of MF300Fm+ Ferrite Meter

Units Ferrite Number FN

Ferrite percentage F%

Range 0 – 115 FN

0 – 80.5% (percent ferrite)

Resolution 0.1  FN

0.1  F%

Standard: Accuracy (10°C – 30°C)

FN 0 – 10

FN 10 – 30

FN 30 – 110

 

± 1 FN

± 10% of the reading

± 20% of the reading

Air cooled: Accuracy (30°C – 300°C)

FN 0 – 10

FN 10 – 30

FN 30 – 100

 

± 1 FN

± 10% of the reading

± 20% of the reading

Calibration Factory calibration to NIST standards

User calibration to supplied transfer standards

Up to 5 calibrations can be supplied (for 5 probes)

Transfer standards Five transfer standards

Range typically 3FN to 115FN

Zero Automatic on demand
Mode Average or peak
Storage 1000 records with 4 character records ID (characters available 0-9, A-Z and space)
PC Download and Upload Optional RS232 and USB

Functions include download of record or part or entire database and upload of record IDs

Probe P46 Pencil style, 15mm diameter length 130mm

Sensing area 4mm×6mm (24mm²)

Sprung loaded sleeve

Probe P10 Pencil style, 15mm diameter length 120mm

Sensing area 10mm diameter (- 80m²)

Operating temperature Standard 0°C – 40°C (P46 and P10)

Air Cooled 0°C – 300°C (P10ac)

Air cooled operation Air line supply regulated to 1 bar maximum

Oil filtered supply desirable

Air temperature: ambient (10°C – 30°C)

Humidity Non-condensing
Weight in case 1.25Kg
Case dimensions 210×100×45mm

Request a free quotation.

Watch the MF300Fm+ in operation.

 

Additional information

Option

, , , , ,

Questions? Ask our specialist team for NDT help or advice